Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Antibiotics (Basel) ; 12(2)2023 Feb 12.
Article in English | MEDLINE | ID: covidwho-2266793

ABSTRACT

BACKGROUND: Lower respiratory tract infections (LRTIs) in primary care are a promising target for antibiotic stewardship. A clinical trial in Switzerland showed a large decrease in antibiotic prescriptions with procalcitonin guidance (cut-off < 0.25 µg/L) compared with usual care. However, one-third of patients with low procalcitonin at baseline received antibiotics by day 28. AIM: To explore the factors associated with the overruling of initial procalcitonin guidance. DESIGN AND SETTING: Secondary analysis of a cluster randomized trial in which patients with an LRTI were included. METHOD: Using the characteristics of patients, their disease, and general practitioners (GPs), we conducted a multivariate logistic regression, adjusted for clustering. RESULTS: Ninety-five out of 301 (32%) patients with low procalcitonin received antibiotics by day 28. Factors associated with an overruling of procalcitonin guidance were: a history of chest pain (adjusted OR [aOR] 1.81, 95% confidence interval 1.03-3.17); a prescription of chest X-ray by the GP (aOR 4.65, 2.32-9.34); a C-reactive protein measured retrospectively above 100 mg/L (aOR 7.48, 2.34-23.93, reference ≤ 20 mg/L); the location of the GP practice in an urban setting (aOR 2.27, 1.18-4.37); and the GP's number of years of experience (aOR per year 1.05, 1.01-1.09). CONCLUSIONS: Overruling of procalcitonin guidance was associated with GPs' socio-demographic characteristics, pointing to the general behavioral problem of overprescription by physicians. Continuous medical education and communication training might support the successful implementation of procalcitonin point-of-care tests aimed at antibiotic stewardship.

2.
PLoS One ; 18(2): e0282150, 2023.
Article in English | MEDLINE | ID: covidwho-2280300

ABSTRACT

BACKGROUND: Nasopharyngeal antigen Rapid Diagnostic Tests (RDTs), saliva RT-PCR and nasopharyngeal (NP) RT-PCR have shown different performance characteristics to detect patients infected by SARS-CoV-2, according to the viral load (VL)-and thus transmissibility. METHODS: In October 2020, we conducted a prospective trial involving patients presenting at testing centres with symptoms of COVID-19. We compared detection rates and performance of RDT, saliva PCR and nasopharyngeal (NP) PCR, according to VL and symptoms duration. RESULTS: Out of 949 patients enrolled, 928 patients had all three tests performed. Detection rates were 35.2% (95%CI 32.2-38.4%) by RDT, 39.8% (36.6-43.0%) by saliva PCR, 40.1% (36.9-43.3%) by NP PCR, and 41.5% (38.3-44.7%) by any test. For those with viral loads (VL) ≥106 copies/ml, detection rates were 30.3% (27.3-33.3), 31.4% (28.4-34.5), 31.5% (28.5-34.6), and 31.6% (28.6-34.7%) respectively. Sensitivity of RDT compared to NP PCR was 87.4% (83.6-90.6%) for all positive patients, 94.5% (91.5-96.7%) for those with VL≥105 and 96.5% (93.6-98.3%) for those with VL≥106. Sensitivity of STANDARD-Q®, Panbio™ and COVID-VIRO® Ag tests were 92.9% (86.4-96.9%), 86.1% (78.6-91.7%) and 84.1% (76.9-89.7%), respectively. For those with VL≥106, sensitivity was 96.6% (90.5-99.3%), 97.8% (92.1-99.7%) and 95.3% (89.4-98.5%) respectively. No patient with VL<104 was detected by RDT. Specificity of RDT was 100% (99.3-100%) compared to any PCR. RDT sensitivity was similar <4 days (87.8%, 83.5-91.3%) and ≥4 days (85.7%, 75.9-92.6%) after symptoms onset (p = 0.6). Sensitivity of saliva and NP PCR were 95.7% (93.1-97.5%) and 96.5% (94.1-98.1%), respectively, compared to the other PCR. CONCLUSIONS: RDT results allow rapid identification of COVID cases with immediate isolation of most contagious individuals. RDT can thus be a game changer both in ambulatory care and community testing aimed at stopping transmission chains, and even more so in resource-constrained settings thanks to its very low price. When PCR is performed, saliva could replace NP swabbing. TRIAL REGISTRATION: ClinicalTrial.gov Identifier: NCT04613310 (03/11/2020).


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Antigens, Viral , COVID-19 Testing , Polymerase Chain Reaction , Prospective Studies , Saliva , Sensitivity and Specificity
3.
Microbiol Spectr ; : e0392322, 2022 Nov 08.
Article in English | MEDLINE | ID: covidwho-2108239

ABSTRACT

In November 2021, the World Health Organization declared the Omicron variant (B.1.1.519) a variant of concern. Since then, worries have been expressed regarding the ability of usual diagnostic tests to detect the Omicron variant. In addition, some recently published data suggested that the salivary reverse transcription (RT)-PCR might perform better than the current gold standard, nasopharyngeal (NP) RT-PCR. In this study, we aimed to compare the sensitivities of nasopharyngeal and saliva RT-PCR and assess the diagnostic performances of rapid antigen testing (RAT) in nasopharyngeal and saliva samples. We conducted a prospective clinical study among symptomatic health care professionals consulting the occupational health service of our hospital for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) screening and hospitalized patients in internal medicine/intensive care wards screened for SARS-CoV-2 with COVID-19-compatible symptoms. A composite outcome considering NP PCR and/or saliva PCR was used as a reference standard to define COVID-19 cases. A total of 475 paired NP/saliva specimens have been collected with a positivity rate of 40% (n = 192). NP and salivary RT-PCR exhibited sensitivities of 98% (95% CI, 94 to 99%) and 87% (95% CI, 81 to 91%), respectively, for outpatients (n = 453) and 94% (95% CI, 72 to 99%) and 69% (95% CI, 44 to 86%), respectively, for hospitalized patients (n = 22). Nasopharyngeal rapid antigen testing exhibited much lower diagnostic performances (sensitivity of 66% and 31% for outpatients and inpatients, respectively), while saliva RAT showed a sensitivity of less than 5% in both groups. Nasopharyngeal RT-PCR testing remains the gold standard for SARS-CoV-2 Omicron variant screening. Salivary RT-PCR can be used as an alternative in case of contraindication to perform NP sampling. The use of RAT should be limited to settings where access to molecular diagnostic methods is lacking. IMPORTANCE The Omicron variant of concern spread rapidly since it was first reported in November 2021 and currently accounts for the vast majority of new infections worldwide. Recent reports suggest that saliva sampling might outweigh nasopharyngeal sampling for the diagnosis of the Omicron variant. Nevertheless, data investigating the best diagnostic strategy specifically for the Omicron variant of concern remain scarce. This study fills this gap in current knowledge and elucidates the question of which strategy to use in which patient. It provides a new basis for further improving COVID-19 screening programs and managing patients suspected to have COVID-19.

4.
Br J Haematol ; 199(4): 549-559, 2022 11.
Article in English | MEDLINE | ID: covidwho-2029286

ABSTRACT

Administration of plasma therapy may contribute to viral control and survival of COVID-19 patients receiving B-cell-depleting agents that impair humoral immunity. However, little is known on the impact of anti-CD20 pre-exposition on the kinetics of SARS-CoV-2-specific antibodies. Here, we evaluated the relationship between anti-spike immunoglobulin G (IgG) kinetics and the clinical status or intra-host viral evolution after plasma therapy in 36 eligible hospitalized COVID-19 patients, pre-exposed or not to B-cell-depleting treatments. The majority of anti-CD20 pre-exposed patients (14/17) showed progressive declines of anti-spike IgG titres following plasma therapy, contrasting with the 4/19 patients who had not received B-cell-depleting agents (p = 0.0006). Patients with antibody decay also depicted prolonged clinical symptoms according to the World Health Organization (WHO) severity classification (p = 0.0267) and SARS-CoV-2 viral loads (p = 0.0032) before complete virus clearance. Moreover, they had higher mutation rates than patients able to mount an endogenous humoral response (p = 0.015), including three patients with one to four spike mutations, potentially associated with immune escape. No relevant differences were observed between patients treated with plasma from convalescent and/or mRNA-vaccinated donors. Our study emphasizes the need for an individualized clinical care and follow-up in the management of COVID-19 patients with B-cell lymphopenia.


Subject(s)
COVID-19 , Humans , COVID-19/therapy , SARS-CoV-2 , Antibody Formation , Immunization, Passive , Antibodies, Viral , Immunoglobulin G
5.
Swiss Med Wkly ; 152: w30168, 2022 05 09.
Article in English | MEDLINE | ID: covidwho-1911922

ABSTRACT

INTRODUCTION: While laboratories have been facing limited supplies of reagents for diagnostic tests throughout the course of the COVID-19 pandemic, national and international health plans, as well as billing costs, have been constantly adjusted in order to optimize the use of resources. We aimed to assess the impact of SARS-CoV-2 test costs and reimbursement tariff adjustments on diagnostic strategies in Switzerland to determine the advantages and disadvantages of different costs and resource saving plans. MATERIALS AND METHODS: We specifically assessed the cost of diagnostic SARS-COV-2 RT-PCR using five different approaches: i) in-house platform, ii) cobas 6800® (Roche, Basel, Switzerland), iii) GeneXpert® SARS-CoV-2 test (Cepheid, Sunnyvale, CA, USA), iv) VIASURE SARS-CoV-2 (N1 + N2) Real-Time PCR Detection Kit for BD MAX™ (Becton Dickinson, Franklin Lake, NJ, USA), v) cobas® Liat® SARS-CoV-2 & Influenza A/B (Roche, Basel, Switzerland). We compared these costs to the evolution of the reimbursement tariffs. RESULTS: The cost of a single RT-PCR test varied greatly (as did the volume of tests performed), ranging from as high as 180 CHF per test at the beginning of the pandemic (February to April 2020) to as low as 82 CHF per test at the end of 2020. Depending on the time period within the pandemic, higher costs did not necessarily mean greater benefits for the laboratories. The costs of molecular reagents for rapid tests were higher than of those for classic RT-PCR platforms, but the rapid tests had reduced turnaround times (TATs), thus improving patient care and enabling more efficient implementation of isolation measures, as well as reducing the burden of possible nosocomial infections. At the same time, there were periods when the production or distribution of these reagents was insufficient, and only the use of several different molecular platforms allowed us to sustain the high number of tests requested. CONCLUSIONS: Cost-saving plans need to be thoroughly assessed and constantly adjusted according to the epidemiological situation, the clinical context and the national resources in order to always guarantee that the highest performing diagnostic solutions are available. Not all cost-saving strategies guarantee good analytical performance.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Clinical Laboratory Techniques , Humans , Pandemics , Sensitivity and Specificity
6.
J Gen Intern Med ; 37(8): 1943-1952, 2022 06.
Article in English | MEDLINE | ID: covidwho-1756889

ABSTRACT

BACKGROUND: After mild COVID-19, some outpatients experience persistent symptoms. However, data are scarce and prospective studies are urgently needed. OBJECTIVES: To characterize the post-COVID-19 syndrome after mild COVID-19 and identify predictors. PARTICIPANTS: Outpatients with symptoms suggestive of COVID-19 with (1) PCR-confirmed COVID-19 (COVID-positive) or (2) SARS-CoV-2 negative PCR (COVID-negative). DESIGN: Monocentric cohort study with prospective phone interview between more than 3 months to 10 months after initial visit to the emergency department and outpatient clinics. MAIN MEASURES: Data of the initial visits were extracted from the electronic medical file. Predefined persistent symptoms were assessed through a structured phone interview. Associations between long-term symptoms and PCR results, as well as predictors of persistent symptoms among COVID-positive, were evaluated by multivariate logistic regression adjusted for age, gender, smoking, comorbidities, and timing of the survey. KEY RESULTS: The study population consisted of 418 COVID-positive and 89 COVID-negative patients, mostly young adults (median age of 41 versus 36 years in COVID-positive and COVID-negative, respectively; p = 0.020) and healthcare workers (67% versus 82%; p = 0.006). Median time between the initial visit and the phone survey was 150 days in COVID-positive and 242 days in COVID-negative patients. Persistent symptoms were reported by 223 (53%) COVID-positive and 33 (37%) COVID-negative patients (p = 0.006) and proportions were stable among the periods of the phone interviews. Overall, 21% COVID-positive and 15% COVID-negative patients (p = 0.182) attended care for this purpose. Four surveyed symptoms were independently associated with COVID-19: fatigue (adjusted odds ratio 2.14, 95% CI 1.04-4.41), smell/taste disorder (26.5, 3.46-202), dyspnea (2.81, 1.10-7.16), and memory impairment (5.71, 1.53-21.3). Among COVID-positive, female gender (1.67, 1.09-2.56) and overweight/obesity (1.67, 1.10-2.56) were predictors of persistent symptoms. CONCLUSIONS: More than half of COVID-positive outpatients report persistent symptoms up to 10 months after a mild disease. Only 4 of 14 symptoms were associated with COVID-19 status. The symptoms and predictors of the post-COVID-19 syndrome need further characterization as this condition places a significant burden on society.


Subject(s)
COVID-19 , Adult , COVID-19/complications , COVID-19/epidemiology , Cohort Studies , Female , Humans , Outpatients , Prospective Studies , SARS-CoV-2 , Young Adult , Post-Acute COVID-19 Syndrome
7.
Front Digit Health ; 3: 773986, 2021.
Article in English | MEDLINE | ID: covidwho-1595837

ABSTRACT

Background: In response to the COVID-19 pandemic, our microbial diagnostic laboratory located in a university hospital has implemented several distinct SARS-CoV-2 RT-PCR systems in a very short time. More than 148,000 tests have been performed over 12 months, which represents about 405 tests per day, with peaks to more than 1,500 tests per days during the second wave. This was only possible thanks to automation and digitalization, to allow high throughput, acceptable time to results and to maintain test reliability. An automated dashboard was developed to give access to Key Performance Indicators (KPIs) to improve laboratory operational management. Methods: RT-PCR data extraction of four respiratory viruses-SARS-CoV-2, influenza A and B and RSV-from our laboratory information system (LIS), was automated. This included age, gender, test result, RT-PCR instrument, sample type, reception time, requester, and hospitalization status etc. Important KPIs were identified and the visualization was achieved using an in-house dashboard based on the open-source language R (Shiny). Results: The dashboard is organized into three main parts. The "Filter" page presents all the KPIs, divided into five sections: (i) general and gender-related indicators, (ii) number of tests and positivity rate, (iii) cycle threshold and viral load, (iv) test durations, and (v) not valid results. Filtering allows to select a given period, a dedicated instrument, a given specimen, an age range or a requester. The "Comparison" page allows a custom charting of all the available variables, which represents more than 182 combination. The "Data" page, gives the user an access to the raw data in tables format, with possibility of filtering, allowing for a deeper analysis and data download. Informations are updated every 4 h. Conclusions: By giving a rapid access to a huge number of up-to-date information, represented using the most relevant visualization types, without the burden of timely data extraction and analysis, the dashboard represents a reliable and user-friendly tool for operational laboratory management. The dashboard represents a reliable and user-friendly tool improving the decision-making process, resource planning and quality management.

8.
Microorganisms ; 9(12)2021 Dec 15.
Article in English | MEDLINE | ID: covidwho-1572565

ABSTRACT

During COVID19 pandemic, SARS-CoV-2 rapid antigen tests (RATs) were marketed with minimal or no performance data. We aimed at closing this gap by determining technical sensitivities and specificities of 30 RATs prior to market release. We developed a standardized technical validation protocol and assessed 30 RATs across four diagnostic laboratories. RATs were tested in parallel using the Standard Q® (SD Biosensor/Roche) assay as internal reference. We used left-over universal transport/optimum media from nasopharyngeal swabs of 200 SARS-CoV-2 PCR-negative and 100 PCR-positive tested patients. Transport media was mixed with assay buffer and applied to RATs according to manufacturer instructions. Sensitivities were determined according to viral loads. Specificity of at least 99% and sensitivity of 95%, 90%, and 80% had to be reached for 107, 106, 105 virus copies/mL, respectively. Sensitivities ranged from 43.5% to 98.6%, 62.3% to 100%, and 66.7% to 100% at 105, 106, 107 copies/mL, respectively. Automated assay readers such as ExDia or LumiraDx showed higher performances. Specificities ranged from 88.8% to 100%. Only 15 of 30 (50%) RATs passed our technical validation. Due to the high failure rate of 50%, mainly caused by lack of sensitivity, we recommend a thorough validation of RATs prior to market release.

9.
J Clin Microbiol ; 60(1): e0169821, 2022 01 19.
Article in English | MEDLINE | ID: covidwho-1511413

ABSTRACT

This first pilot trial on external quality assessment (EQA) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) whole-genome sequencing, initiated by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Genomic and Molecular Diagnostics (ESGMD) and the Swiss Society for Microbiology (SSM), aims to build a framework between laboratories in order to improve pathogen surveillance sequencing. Ten samples with various viral loads were sent out to 15 clinical laboratories that had free choice of sequencing methods and bioinformatic analyses. The key aspects on which the individual centers were compared were the identification of (i) single nucleotide polymorphisms (SNPs) and indels, (ii) Pango lineages, and (iii) clusters between samples. The participating laboratories used a wide array of methods and analysis pipelines. Most were able to generate whole genomes for all samples. Genomes were sequenced to various depths (up to a 100-fold difference across centers). There was a very good consensus regarding the majority of reporting criteria, but there were a few discrepancies in lineage and cluster assignments. Additionally, there were inconsistencies in variant calling. The main reasons for discrepancies were missing data, bioinformatic choices, and interpretation of data. The pilot EQA was overall a success. It was able to show the high quality of participating laboratories and provide valuable feedback in cases where problems occurred, thereby improving the sequencing setup of laboratories. A larger follow-up EQA should, however, improve on defining the variables and format of the report. Additionally, contamination and/or minority variants should be a further aspect of assessment.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Laboratories , Laboratories, Clinical , Pilot Projects
10.
Front Cell Infect Microbiol ; 11: 594577, 2021.
Article in English | MEDLINE | ID: covidwho-1444038

ABSTRACT

Since the beginning of the COVID-19 pandemic, important health and regulatory decisions relied on SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR) results. Our diagnostic laboratory faced a rapid increase in the number of SARS-CoV-2 RT-PCR. To maintain a rapid turnaround time, we moved from a case-by-case validation of RT-PCR results to an automated validation and immediate results transmission to clinicians. A quality-monitoring tool based on a homemade algorithm coded in R was developed, to preserve high quality and to track aberrant results. We present the results of this quality-monitoring tool applied to 35,137 RT-PCR results. Patients tested several times led to 4,939 pairwise comparisons: 88% concordant and 12% discrepant. The algorithm automatically solved 428 out of 573 discrepancies. The most likely explanation for these 573 discrepancies was related for 44.9% of the situations to the clinical evolution of the disease, 27.9% to preanalytical factors, and 25.3% to stochasticity of the assay. Finally, 11 discrepant results could not be explained, including 8 for which clinical data was not available. For patients repeatedly tested on the same day, the second result confirmed a first negative or positive result in 99.2% or 88.9% of cases, respectively. The implemented quality-monitoring strategy allowed to: i) assist the investigation of discrepant results ii) focus the attention of medical microbiologists onto results requiring a specific expertise and iii) maintain an acceptable turnaround time. This work highlights the high RT-PCR consistency for the detection of SARS-CoV-2 and the necessity for automated processes to handle a huge number of microbiological results while preserving quality.


Subject(s)
COVID-19 , SARS-CoV-2 , Computers , Humans , Pandemics , Reverse Transcriptase Polymerase Chain Reaction , Sensitivity and Specificity
11.
Microorganisms ; 9(9)2021 Sep 09.
Article in English | MEDLINE | ID: covidwho-1410331

ABSTRACT

Saliva sampling could serve as an alternative non-invasive sample for SARS-CoV-2 diagnosis while rapid antigen tests (RATs) might help to mitigate the shortage of reagents sporadically encountered with RT-PCR. Thus, in the RESTART study we compared antigen and RT-PCR testing methods on nasopharyngeal (NP) swabs and salivary samples. We conducted a prospective observational study among COVID-19 hospitalized patients between 10 December 2020 and 1 February 2021. Paired saliva and NP samples were investigated by RT-PCR (Cobas 6800, Roche-Switzerland, Basel, Switzerland) and by two rapid antigen tests: One Step Immunoassay Exdia® COVID-19 Ag (Precision Biosensor, Daejeon, Korea) and Standard Q® COVID-19 Rapid Antigen Test (Roche-Switzerland). A total of 58 paired NP-saliva specimens were collected. A total of 32 of 58 (55%) patients were hospitalized in the intensive care unit, and the median duration of symptoms was 11 days (IQR 5-19). NP and salivary RT-PCR exhibited sensitivity of 98% and 69% respectively, whereas the specificity of these RT-PCRs assays was 100%. The NP RATs exhibited much lower diagnostic performance, with sensitivities of 35% and 41% for the Standard Q® and Exdia® assays, respectively, when a wet-swab approach was used (i.e., when the swab was diluted in the viral transport medium (VTM) before testing). The sensitivity of the dry-swab approach was slightly better (47%). These antigen tests exhibited very low sensitivity (4% and 8%) when applied to salivary swabs. Nasopharyngeal RT-PCR is the most accurate test for COVID-19 diagnosis in hospitalized patients. RT-PCR on salivary samples may be used when nasopharyngeal swabs are contraindicated. RATs are not appropriate for hospitalized patients.

12.
Swiss Med Wkly ; 151: w30057, 2021 08 30.
Article in English | MEDLINE | ID: covidwho-1403974

ABSTRACT

In anticipation of an interseasonal respiratory syncytial virus (RSV) epidemic, a clinician-led reporting system was rapidly established to capture RSV infections in Swiss hospitals, starting in January 2021. Here, we present details of the reporting system and first results to June 2021. An unusual epidemiology was observed with an interseasonal surge of RSV infections associated with COVID-19-related non-pharmacological interventions. These data allowed real-time adjustment of RSV prophylaxis guidelines and consequently underscore the need for and continuation of systematic nationwide RSV surveillance.


Subject(s)
COVID-19 , Respiratory Syncytial Virus Infections , Respiratory Syncytial Virus, Human , Respiratory Tract Infections , Humans , Infant , Respiratory Syncytial Virus Infections/epidemiology , Respiratory Syncytial Virus Infections/prevention & control , SARS-CoV-2 , Switzerland/epidemiology
13.
Pediatr Infect Dis J ; 40(8): e300-e304, 2021 08 01.
Article in English | MEDLINE | ID: covidwho-1305447

ABSTRACT

BACKGROUND: Saliva reverse transcriptase-Polymerase chain reaction (RT-PCR) is an attractive alternative for the detection of severe acute respiratory syndrome coronavirus 2 in adults with less known in children. METHODS: Children with coronavirus disease 2019 symptoms were prospectively enrolled in a 1-month comparative clinical trial of saliva and nasopharyngeal (NP) RT-PCR. Detection rates and sensitivities of saliva and NP RT-PCR were compared as well as discordant NP and saliva RT-PCR findings including viral loads (VLs). RESULTS: Of 405 patients enrolled, 397 patients had 2 tests performed. Mean age was 12.7 years (range, 1.2-17.9). Sensitivity of saliva was 85.2% (95% confidence interval: 78.2%-92.1%) when using NP as the standard; sensitivity of NP was 94.5% (89.8%-99.2%) when saliva was considered as the standard. For a NP RT-PCR VL threshold of ≥103 and ≥104 copies/mL, sensitivity of saliva increases to 88.7% and 95.2%, respectively. Sensitivity of saliva and NP swabs was, respectively, 89.5% and 95.3% in patient with symptoms less than 4 days (P = 0.249) and 70.0% and 95.0% in those with symptoms ≥4-7 days (P = 0.096). The 15 patients who had an isolated positive NP RT-PCR were younger (P = 0.034), had lower NP VL (median 5.6 × 103 vs. 3.9 × 107, P < 0.001), and could not drool saliva at the end of the sampling (P = 0.002). VLs were lower with saliva than with NP RT-PCR (median 8.7 cp/mL × 104; interquartile range 1.2 × 104-5.2 × 105; vs. median 4.0 × 107 cp/mL; interquartile range, 8.6 × 105-1 × 108; P < 0.001). CONCLUSIONS: While RT-PCR testing on saliva performed more poorly in younger children and likely after longer duration of symptoms, saliva remains an attractive alternative to NP swabs in children.


Subject(s)
COVID-19 Testing , COVID-19/diagnosis , COVID-19/virology , Nasopharynx/virology , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/isolation & purification , Saliva/virology , Child , Child, Preschool , Diagnostic Tests, Routine , Female , Humans , Infant , Infant, Newborn , Male , Prospective Studies , SARS-CoV-2/genetics , Sensitivity and Specificity , Specimen Handling , Viral Load
14.
Sci Total Environ ; 787: 147483, 2021 Sep 15.
Article in English | MEDLINE | ID: covidwho-1230768

ABSTRACT

To understand the geographical and temporal spread of SARS-CoV-2 during the first documented wave of infection in the state of Vaud, Switzerland, we analyzed clusters of positive cases using the precise residential location of 33,651 individuals tested (RT-PCR) between January 10 and June 30, 2020. We used a prospective Poisson space-time scan statistic (SaTScan) and a Modified Space-Time Density-Based Spatial Clustering of Application with Noise (MST-DBSCAN) to identify both space-time and transmission clusters, and estimated cluster duration, transmission behavior (emergence, growth, reduction, etc.) and relative risk. For each cluster, we computed the number of individuals, the median age of individuals and their viral load. Among the 1684 space-time clusters identified, 457 (27.1%) were significant (p ≤ 0.05), such that they harbored a higher relative risk of infection within the cluster than compared to regions outside the cluster. Clusters lasted a median of 11 days (IQR 7-13) and included a median of 12 individuals per cluster (IQR 5-20). The majority of significant clusters (n = 260; 56.9%) had at least one person with an extremely high viral load (>1 billion copies/ml). Those clusters were considerably larger (median of 17 infected individuals, p < 0.001) than clusters with individuals showing a viral load below 1 million copies/ml (median of three infected individuals). The highest viral loads were found in clusters with the lowest average age group considered in the investigation, while clusters with the highest average age had low to middle viral load. In 20 significant clusters, the viral load of the three first cases was below 100,000 copies/ml, suggesting that subjects with fewer than 100,000 copies/ml may still be contagious. Notably, the dynamics of transmission clusters made it possible to identify three diffusion zones, which predominantly differentiated between rural and urban areas, the latter being more prone to persistence and expansion, which may result in the emergence of new clusters nearby. The use of geographic information is key for public health decision makers in mitigating the spread of the SARS-CoV-2 virus. This study suggests that early localization of clusters may help implement targeted protective measures limiting the spread of the virus.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Prospective Studies , Switzerland/epidemiology , Viral Load
15.
J Med Microbiol ; 70(5)2021 May.
Article in English | MEDLINE | ID: covidwho-1218065

ABSTRACT

Introduction. Clinical microbiology laboratories have had to cope with an increase in the volume of tests due to the emergence of the SARS-CoV-2 virus. Short turnaround times (TATs) are important for case tracing and to help clinicians in patient management. In such a context, high-throughput systems are essential to process the bulk of the tests. Rapid tests are also required to ensure shorter TATs for urgent situations. In our laboratory, SARS-CoV-2 assays were initially implemented on our custom platform using a previously published method. The commercial cobas 6800 (Roche diagnostics) assay and the GeneXpert Xpress (Cepheid) SARS-CoV-2 assay were implemented on 24 March and 8 April 2020, respectively, as soon as available.Hypothesis/Gap Statement. Despite the abundant literature on SARS-CoV-2 assays, the articles focus mainly on the diagnostic performances. This is to our knowledge the first article that specifically studies the TAT of different assays.Aim. We aimed to describe the impact of various SARS-CoV-2 assays on the TAT at the beginning of the outbreak.Methodology. In this study, we retrospectively analysed the TAT of all SARS-CoV-2 assays performed in our centre between 24 February and 9 June, 2020.Results. We retrieved 33 900 analyses, with a median TAT of 6.25 h. TATs were highest (6.9 h) when only our custom platform was used (24 February to 24 March, 2020). They were reduced to 6.1 h when the cobas system was introduced (24 March to 8 April, 2020). The implementation of the GeneXpert further reduced the median TAT to 4.8 h (8 April to 9 June, 2020). The GeneXpert system had the shortest median TAT (1.9 h), followed by the cobas (5.5 h) and by our custom platform (6.9 h).Conclusion. This work shows that the combination of high-throughput systems and rapid tests allows the efficient processing of a large number of tests with a short TAT. In addition, the use of a custom platform allowed the quick implementation of an in-house test when commercial assays were not yet available.


Subject(s)
COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Contact Tracing , High-Throughput Screening Assays , Hospitals, University , Humans , Retrospective Studies , Switzerland , Time Factors
16.
Microorganisms ; 9(4)2021 Mar 25.
Article in English | MEDLINE | ID: covidwho-1154452

ABSTRACT

The rapid spread of the SARS-CoV-2 lineages B.1.1.7 (N501Y.V1) throughout the UK, B.1.351 (N501Y.V2) in South Africa, and P.1 (B.1.1.28.1; N501Y.V3) in Brazil has led to the definition of variants of concern (VoCs) and recommendations for lineage specific surveillance. In Switzerland, during the last weeks of December 2020, we established a nationwide screening protocol across multiple laboratories, focusing first on epidemiological and microbiological definitions. In January 2021, we validated and implemented an N501Y-specific PCR to rapidly screen for VoCs, which are then confirmed using amplicon sequencing or whole genome sequencing (WGS). A total of 13,387 VoCs have been identified since the detection of the first Swiss case in October 2020, with 4194 being B.1.1.7, 172 B.1.351, and 7 P.1. The remaining 9014 cases of VoCs have been described without further lineage specification. Overall, all diagnostic centers reported a rapid increase of the percentage of detected VOCs, with a range of 6 to 46% between 25 to 31 of January 2021 increasing towards 41 to 82% between 22 to 28 of February. A total of 739 N501Y positive genomes were analysed and show a broad range of introduction events to Switzerland. In this paper, we describe the nationwide coordination and implementation process across laboratories, public health institutions, and researchers, the first results of our N501Y-specific variant screening, and the phylogenetic analysis of all available WGS data in Switzerland, that together identified the early introduction events and subsequent community spreading of the VoCs.

17.
Pathog Dis ; 78(8)2020 11 11.
Article in English | MEDLINE | ID: covidwho-837139

ABSTRACT

OBJECTIVES: In order to cope with the rapid spread of the COVID-19 pandemic, we introduced on our in-house high-throughput molecular diagnostic platform (MDx Platform) a real-time reverse transcriptase PCR (RT-PCR) to detect the SARS-CoV-2 from any clinical specimens. The aim of this study was to compare the RT-PCR results obtain with the MDx Platform and the commercial assay cobas SARS-CoV-2 (Roche) on nasopharyngeal swab and other clinical specimens including sputum, bronchial aspirate, bronchoalveolar lavage and anal swabs. METHODS: Samples received in our laboratory from patients suspected of COVID-19 (n = 262) were tested in parallel with our MDx platform SARS-CoV-2 PCR and with the cobas SARS-CoV-2 test. RESULTS: The overall agreement between the two tests for all samples tested was 99.24% (260/262), which corresponded to agreements of 100% (178/178) on nasopharyngeal swabs, 95.45% (42/44) on lower respiratory tract specimen with discordant resultS obtained for very high cycle threshold (Ct) value and 100% (40/40) on anorectal swabs. The Ct values for nasopharyngeal swabs displayed an excellent correlation (R2 > 96%) between both tests. CONCLUSIONS: The high agreements between the cobas SARS-CoV-2 test and the MDx platform supports the use of both methods for the diagnostic of COVID-19 on various clinical samples. Very few discrepant results may occur at very low viral load.


Subject(s)
Betacoronavirus/isolation & purification , Coronavirus Infections/diagnosis , High-Throughput Nucleotide Sequencing/methods , Molecular Diagnostic Techniques/instrumentation , Molecular Diagnostic Techniques/methods , Pneumonia, Viral/diagnosis , Reverse Transcriptase Polymerase Chain Reaction/methods , COVID-19 , Coronavirus Infections/virology , Humans , Nasopharynx/virology , Pandemics , Pneumonia, Viral/virology , SARS-CoV-2
18.
Microbes Infect ; 22(10): 617-621, 2020.
Article in English | MEDLINE | ID: covidwho-745971

ABSTRACT

RT-PCRs to detect SARS-CoV-2 RNA is key to manage the COVID-19 pandemic. We analyzed SARS-CoV-2 viral loads from 22'323 RT-PCR results according to samples types, gender, age, and health units. Viral load did not show any difference across age and appears to be a poor predictor of disease outcome. SARS-CoV-2 viral load showed similar high viral loads than the one observed for RSV and influenza B. The importance of viral load to predict contagiousness and to assess disease progression is discussed.


Subject(s)
COVID-19/virology , Coronavirus Infections/virology , SARS-CoV-2/isolation & purification , Viral Load/statistics & numerical data , Adolescent , Adult , Aged , Aged, 80 and over , COVID-19/diagnosis , COVID-19 Nucleic Acid Testing , Child , Child, Preschool , Coronavirus Infections/diagnosis , Disease Progression , Female , Humans , Infant , Infant, Newborn , Influenza B virus/isolation & purification , Influenza, Human/virology , Male , Middle Aged , Pandemics , Respiratory Syncytial Virus Infections/virology , Respiratory Syncytial Viruses/isolation & purification , Serologic Tests/methods , Switzerland/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL